HOT WATER OUTLET • ENVIROSUN

Envirosun Hot Water Systems from $2,179

Shop Envirosun hot water systems with clear product pricing, fast delivery options and the parts you need available on each product page.
24
Same Day Delivery on Over 70% of Our Range Order before 8am for Same Day Delivery on eligible products and metro delivery areas.
FAST DELIVERY

Why customers choose Hot Water Outlet

Shop hot water systems, valves, fittings, pumps, filters, and accessories online with clear product details, competitive pricing, helpful support, and delivery to eligible Australian postcodes.

4 products
Recently viewed
Envirosun Hot Water Systems Australia

Envirosun Hot Water Systems

Compare Envirosun heat pumps, solar hot water and gas continuous-flow systems, plus related Enviroheat models, by size, technology and current supply-only price.

Systems from $2,179
3 Current SystemsCompare the Envirosun and related heat-pump systems currently available to order.
Heat Pump, Solar & GasUnderstand the full Envirosun range, not just the products currently stocked.
One Envirosun Buying GuideModels, sizing, pricing, replacement advice, rebates and common questions.

Envirosun is an Australian-owned hot-water brand with roots in the Australian solar industry and is now part of Energie Group Australia. The current Envirosun range covers HP Plus M9 and HP Classic heat pumps, roof-mounted and split solar hot water, and Endless gas continuous flow. The brand’s product development is Australian-led, with components and manufacturing sourced across Australia and overseas depending on the product.

Use this page as the main Envirosun topical hub. Compare the M9 200 and 330, understand the older/classic 250L heat-pump platform and Enviroheat relationship, compare solar thermosiphon with active split systems, learn how the Endless gas range differs from stored hot water, check sizing and installation considerations, and compare current HWO pricing before ordering.

Envirosun Hot Water Range Explained

Envirosun’s current range is built around three main technologies: heat pump, solar and gas continuous flow. Heat pumps and solar use renewable heat sources to reduce purchased energy, while the Endless gas family provides compact on-demand hot water without a storage tank.

Heat PumpHP Plus M9

190L and 330L inverter heat pumps using R290 refrigerant and quiet 42dB(A) operation.

Heat PumpHP Classic 250

Established 246L platform using R134a refrigerant and a 1.5kW electric backup element.

Solar Roof-MountedTS / THX Range

167L and 304L thermosiphon solar systems with electric or gas boosting.

Solar SplitAS Active Split

320L and 420L ground tanks with roof collectors and pumped circulation.

Gas Continuous FlowCF Endless

20L/min and 26L/min Natural Gas or LPG continuous-flow systems.

Envirosun HP Plus

Envirosun M9 200L & 330L Heat Pumps

The HP Plus M9 is Envirosun’s newer inverter heat-pump platform. The ES200M9 has 190L total water capacity while the ES330M9 has 330L. Both use R290 refrigerant, a 1.5kW electric backup element, inverter heat-pump technology and a 42dB(A) sound-pressure rating.

Envirosun lists an ambient operating range from -7°C to 45°C for the M9. The 200 model is broadly positioned for 2–4 people and the 330 for 4–6 people, but actual household suitability depends on shower duration, baths, recovery timing and how heavily hot water is used back-to-back.

M9 200 / ES200M9

190L total capacity, 3.2kW average heat-pump heating capacity at stated test conditions, R290 refrigerant and a compact 580 × 620mm footprint. It is the smaller M9 for lower to medium household demand.

M9 330 / ES330M9

330L total capacity with approximately 3.3kW average heat-pump heating capacity at stated conditions. The larger tank provides more stored reserve for higher-demand homes.

R290 & Inverter Technology

R290 is a low-GWP refrigerant. The inverter compressor can vary output instead of operating only at one fixed speed, helping the system balance recovery, efficiency and noise.

Noise & Siting

Envirosun rates both M9 models at 42dB(A). Even a quiet heat pump still needs sensible placement away from bedrooms and noise-sensitive boundaries, with adequate airflow and service clearances.

Envirosun / Enviroheat Heritage

HP Classic 250 & Enviroheat Heat Pumps

The Envirosun HP Classic 250 is the established 246L-class heat-pump platform. It uses R134a refrigerant, an approximately 1.5kW electric backup element and a 46dB(A) sound-pressure rating. The platform has been used across the wider Energie Group hot-water family and is distinct from the newer R290 M9 series.

Enviroheat is a separate Energie Group brand introduced for heat-pump hot water. HWO may list Enviroheat models alongside Envirosun because of the shared group and product lineage. Do not assume the Envirosun and Enviroheat names make every model identical: use the full model code and current specification when comparing capacity, refrigerant, controls and warranty.

M9 vs Classic 250

M9 uses the newer R290 inverter platform and is available in 190L and 330L capacities. Classic 250 uses the proven 246L R134a platform. The decision should consider household demand, physical size, noise, refrigerant, controls, current warranty and purchase price.

How Heat Pumps Work

How an Envirosun Heat Pump Heats Water

A heat pump works like a refrigerator in reverse. A fan moves ambient air across an evaporator, refrigerant absorbs that heat, the compressor raises the refrigerant temperature and the condenser transfers the heat into the stored water. Because the system moves heat rather than creating all of it with a resistive element, electricity use can be substantially lower than conventional electric storage under suitable conditions.

Electric Backup Element

Current M9 and Classic models include a 1.5kW element. Depending on operating mode and conditions, it can assist with fast recovery, high-temperature cycles or low-ambient operation.

Solar PV Timing

Heat pumps can be scheduled to operate during daylight hours so rooftop solar PV generation is used when available. The best timer strategy depends on household use, tariff and the product controls.

Condensate

Heat pumps remove moisture from the air as they operate, so condensate needs a suitable drain path. This is normal operation and should be planned during installation.

Airflow

The heat-pump section needs free airflow. Enclosing the unit tightly or restricting air movement can reduce performance and create service-access problems.

Envirosun Solar Hot Water

Envirosun TS, THX & AS Solar Hot Water

Envirosun’s solar range has two main layouts. TS and THX are roof-mounted thermosiphon systems where the storage tank and collectors sit together on the roof. AS Active Split separates the tank and collectors, leaving the collectors on the roof and placing the larger storage cylinder at ground level.

TS Thermosiphon

Available around 167L and 304L. Natural thermosiphon circulation moves heated water without a solar circulation pump. Current systems use stainless-steel tanks and can be electrically or gas boosted.

THX Freeze-Protected Solar

The closed-circuit THX configuration is intended for areas needing additional freeze protection. It still uses roof-mounted tank-and-collector construction but separates the potable water from the collector heat-transfer circuit.

AS Active Split

Available around 320L and 420L, with ground-mounted storage and roof collectors. A controlled circulation pump moves solar-heated fluid or water between collectors and tank depending on system configuration.

Electric vs Gas Boost

Solar still needs backup for periods of low solar gain or unusually high demand. Envirosun offers electric-boosted and gas-boosted configurations across parts of the solar range.

Envirosun Endless Gas

Envirosun Continuous-Flow Gas Hot Water

The CF Endless Series is Envirosun’s gas continuous-flow range. Current products are available in 20L/min and 26L/min Natural Gas and LPG versions with a 6.2-star gas energy rating. Unlike a storage system, Endless heats water as it flows through the appliance.

Model classFlowTypical comparisonKey checks
Endless 2020L/minLower to medium simultaneous hot-water demand.Natural Gas/LPG, gas supply, water pressure, temperature setting and power.
Endless 2626L/minHigher simultaneous demand and larger households.Gas type, gas pipe capacity, water flow, power and likely simultaneous outlets.

The range uses direct ignition, WaterServo temperature/flow control and FlameSustain technology. Envirosun lists 11 temperature set points from 38°C to 75°C, with 50°C factory presets on relevant models. LPG versions are specified for propane and must match the fuel supply.

Envirosun Sizing Guide

What Size Envirosun Hot Water System Do I Need?

For stored hot water, size from actual daily demand rather than household size alone. A useful guide is around 40L per person per day for light use, 50L average, 65L high use and 80L very heavy use. Heat-pump recovery and operating schedule then determine how much stored reserve is required.

40LLight use / person / dayShort showers and lower overall demand.
50LAverage use / person / dayA practical starting point for everyday household sizing.
65LHigh use / person / dayLonger showers, baths or frequent back-to-back demand.
80LVery heavy use / person / dayA useful stress-test for unusually high demand.
M9 200 vs M9 330

The 200 gives a compact 190L total capacity and suits lower-demand homes. The 330 gives substantially more stored water and is the better starting point where several people shower close together, bath use is common or the home needs a larger overnight reserve.

Envirosun Buying Comparisons

How the Main Envirosun Options Compare

Envirosun typeHeating methodHow to sizeMain site checksCommon reason to choose it
M9 Heat PumpR290 inverter heat pump + element.190L or 330L + recovery.Airflow, noise, condensate, power and footprint.Efficient electric hot water with modern low-GWP refrigerant.
Classic 250 Heat PumpR134a heat pump + element.246L + recovery.Airflow, power, condensate and available height.Proven mid-size heat-pump platform.
TS / THX SolarRoof solar collectors + booster.167L or 304L + collector area.Roof load, sun, orientation, freeze zone and booster.Roof-mounted solar with no separate ground tank.
AS Split SolarRoof collectors + pumped ground tank.320L or 420L + collectors.Roof, pump/controller, tank site and booster.Large solar capacity with ground-level storage.
Endless GasGas continuous flow.20 or 26L/min + simultaneous demand.Gas type, supply capacity, water pressure and power.On-demand hot water without tank storage.
Replacement Guide

Replacing an Existing Hot Water System with Envirosun

The simplest replacement is usually the closest technology match, but Envirosun is often considered when moving from conventional electric storage to heat pump or when replacing older solar hot water. Changing technology can reduce running costs but adds site checks that a straightforward tank swap may not need.

1Identify the Old System

Record tank size, energy source, model, dimensions and current connection requirements.

2Confirm Demand

Consider household size, shower habits, baths and whether the existing unit runs out.

3Check the Site

Measure clearances and check airflow, condensate, power, roof or gas requirements.

4Choose the Technology

Compare M9, Classic, solar or continuous flow against the existing setup and future energy goals.

Electric Storage to M9

A common upgrade path. Check power supply, airflow, condensate, noise, footprint and whether 190L or 330L better matches household demand.

Old Heat Pump to M9

Compare actual storage volume, height, width, plumbing connection positions, electrical supply and condensate before assuming a direct replacement.

Old Solar to New Envirosun Solar

Determine whether the existing system is thermosiphon or split, collector count, booster type, roof suitability and tank location before selecting TS, THX or AS.

Gas Storage to Endless

Moving to continuous flow removes stored capacity but changes sizing to L/min and may require changes to gas pipe, power, water flow and installation location.

STCs & Renewable Hot Water

Envirosun Rebates & STC Eligibility

Eligible Envirosun heat-pump and solar systems can create Small-scale Technology Certificates when installed in accordance with the scheme rules. The number and value of certificates depends on the exact registered model, installation date, geographic zone and current scheme settings. State-based incentives can have additional eligibility rules.

Do not choose a system solely from a headline rebate amount. Compare the post-rebate purchase and installation cost, household demand, expected electricity or gas use, warranty and the suitability of the installation site.

Dimensions, Noise & Connections

Will an Envirosun Heat Pump Fit My Existing Location?

Check the exact product dimensions and filled weight rather than relying on the marketed litre class. The M9 200 is approximately 580 × 620 × 1746mm and can weigh around 282kg when filled, while the M9 330 is substantially larger at about 710 × 740 × 1923mm and around 449kg filled. The 250 Classic is taller again at around 1987mm.

Heat pumps also need clear airflow, condensate drainage and sensible acoustic placement. Water pressure, PTR/ECV requirements, hot and cold connection positions and access for future service should all be checked before ordering.

Current Supply-Only Pricing

Envirosun Hot Water System Prices

Compare current product prices, then open the system to check stock, specifications, delivery and optional parts.

SystemCurrent pricePurchase type
Envirosun M9 330L Heat Pump Hot Water System$2,359Supply onlyView
Enviroheat 250L Heat Pump Hot Water System$2,179Supply onlyView
Envirosun M9 200L Heat Pump Hot Water System$2,319Supply onlyView

Product price only. Delivery, valves, fittings, pipework, installation and other extras are separate unless expressly included with the selected product.

Warranty, Water Quality & Care

Envirosun Warranty & Maintenance

Warranty depends on the exact model and purchase date. Envirosun currently promotes a 10-year transferable warranty across its current range subject to the applicable terms, while older Enviroheat heat pumps can use different tank, compressor, parts and labour periods.

Magnesium Anodes

Current M9 and Classic heat-pump specifications use magnesium-anode corrosion protection. Anode condition and water quality can affect cylinder life, so follow the maintenance requirements for the exact model.

Water Quality

Envirosun installation material sets water-quality limits for some product families. High hardness, dissolved solids, chloride or other out-of-range water conditions can affect warranty and service life.

Heat-Pump Components

A heat pump combines the tank, compressor, fan, controls, refrigerant circuit and backup element. A fault in one component does not automatically mean the cylinder itself has failed.

Keep the Model Code

Record ES200M9, ES330M9 or the exact Enviroheat model number. The model code is important for warranty, spare parts, technical support and future replacement matching.

Repair or Replace?

Common Envirosun Heat Pump Problems & Replacement Signs

A heat pump that stops producing hot water does not automatically need complete replacement. Power-supply issues, operating mode, sensors, fan/compressor faults, refrigerant-system faults, electric-element problems or control errors can all affect operation. A leaking cylinder, major corrosion or repeated high-cost failures are stronger replacement indicators.

Not Heating

Check the system is powered and that the selected operating mode and timer are appropriate. Electrical and refrigeration diagnostics should be completed by the appropriate licensed trade.

Long Recovery

Heavy demand, low ambient temperature, operating mode, restricted airflow or a fault can all increase recovery time. Compare actual use against the selected tank size before assuming the unit is undersized.

Excessive Noise

Normal fan and compressor operation creates some sound, but new vibration, rattling or abnormal compressor noise should be investigated.

Water Around the Unit

Condensate can be normal. Water from plumbing connections, relief valves or the cylinder is different and should be identified before deciding whether repair or replacement is required.

Ordering from Hot Water Outlet

Buying an Envirosun Hot Water System Supply Only

Choose the system first, then check delivery and add only the valves, pipework, fittings or accessories required for the job. For a replacement, the old model number, capacity, energy source, dimensions and a clear photo of the existing installation make product matching much easier.

Envirosun FAQ

Envirosun Hot Water System Questions

Answers to common Envirosun price, M9, Enviroheat, heat-pump, solar, gas, sizing, replacement, warranty and rebate questions.

Envirosun price questions
How much does an Envirosun M9 200L heat pump cost?
The Envirosun M9 200L heat pump currently starts from $2,319 supply only. The M9 200 is the compact model in the current HP Plus M9 range, with 190L total water capacity, R290 refrigerant and 42dB(A) operation.
How much does an Envirosun M9 330L heat pump cost?
The Envirosun M9 330L heat pump currently starts from $2,359 supply only. It provides 330L total water capacity and is the larger M9 option for higher household hot-water demand.
How much does an Enviroheat 250L heat pump cost?
The Enviroheat 250L heat pump currently starts from $2,179 supply only. This is the established 246L-class heat-pump platform associated with the same Australian hot-water group as Envirosun.
How much does an Enviroheat 200L heat pump cost?
The Enviroheat 200L is not currently available in this range. Check the available Envirosun M9 200L and other heat-pump options on this page.
How much does an Envirosun heat pump cost?
Envirosun-branded heat pumps on this page currently start from $2,319 supply only. Compare capacity, noise, refrigerant, recovery and household demand before choosing on price alone.
What do the Envirosun M9 200 and 330 cost?
The M9 range currently spans from $2,319 for the 200L-class model to $2,359 for the 330L model. Choose primarily by household demand, available space and recovery needs rather than the price gap alone.
How much does an Enviroheat heat pump cost?
Enviroheat heat pumps in this collection currently start from $2,179 supply only. Enviroheat is a separate Energie Group brand with shared hot-water engineering heritage alongside Envirosun.
What do Envirosun heat pump hot water systems start from?
Heat-pump systems in this Envirosun collection currently start from $2,179 supply only. Compare the Envirosun M9 and Enviroheat models by capacity, recovery, noise, refrigerant and warranty.
What is the price difference between Envirosun M9 200 and M9 330?
The Envirosun M9 200 is currently $2,319 and the M9 330 is $2,359 supply only. The larger model adds significantly more stored water, so the right choice depends on household demand rather than price alone.
What is the cheapest Envirosun or Enviroheat system at Hot Water Outlet?
The lowest current supply-only price among available hot-water systems in this Envirosun collection is $2,179. Check the product type and capacity carefully because the collection can include both Envirosun and Enviroheat heat pumps.
Envirosun product & brand questions
What types of Envirosun hot water systems are available?
Envirosun’s current Australian range spans heat pumps, solar hot water and gas continuous flow. Current product families include HP Plus M9 and HP Classic heat pumps, TS thermosiphon solar, AS Active Split solar and CF Endless gas continuous-flow systems.
What is the Envirosun M9 heat pump range?
The Envirosun HP Plus M9 range has two sizes: ES200M9 with 190L total water capacity and ES330M9 with 330L. Both use inverter heat-pump technology, R290 refrigerant, a 1.5kW electric element, 42dB(A) sound pressure and an operating range down to -7°C.
Should I choose Envirosun M9 200 or M9 330?
The M9 200 is aimed at lower to medium household demand, while the M9 330 provides substantially more stored water for higher-demand homes. Envirosun positions them broadly for 2–4 and 4–6 people respectively, but shower habits and recovery requirements still matter.
What is the difference between Envirosun M9 and HP Classic 250?
The HP Classic 250 uses a different established heat-pump platform from the M9. It has approximately 246L tank volume, R134a refrigerant and a 46dB(A) sound level, while the M9 uses R290, inverter technology and 42dB(A) operation.
What is the relationship between Envirosun and Enviroheat?
Envirosun and Enviroheat are separate brands with shared history under Energie Group Australia. Enviroheat was introduced as a heat-pump brand, while Envirosun is the group’s broader flagship hot-water brand covering solar, heat pump and gas systems. Some product families share engineering lineage, so always use the exact model code when comparing specifications or warranties.
What Envirosun solar hot water systems are available?
Envirosun TS solar systems are roof-mounted thermosiphon systems available around 167L and 304L, while the AS Active Split range uses roof collectors with a ground-level 320L or 420L tank. Both ranges can use electric or gas boosting depending on configuration.
What Envirosun gas hot water systems are available?
Envirosun Endless gas continuous-flow systems are available in 20L/min and 26L/min Natural Gas and LPG versions. They carry a 6.2-star gas energy rating, use direct ignition and offer adjustable temperature settings across supported installations.
Can I buy an Envirosun hot water system supply only?
Yes. Hot Water Outlet is set up for supply-only purchasing. Choose the Envirosun system first, then add valves, fittings, pipework or other accessories required for the job where available.
What warranty does an Envirosun hot water system have?
Envirosun warranty coverage is model-specific. Current Envirosun marketing promotes 10-year transferable warranties across its current range subject to the applicable terms, while older Enviroheat products can use different warranty periods. Check the exact model warranty before purchase.
Can an Envirosun heat pump replace an electric hot water system?
For the simplest replacement, identify the existing system type, tank capacity, dimensions, electrical or gas connection and household demand. Replacing electric storage with an Envirosun heat pump can reduce electricity use, but airflow, condensate drainage, noise, electrical supply and physical clearance all need to be checked.